Overview

The Platelet Function Analyzer (PFA-100 / 200) is a lab test designed to assess how well platelets—tiny cell fragments that help clot blood—are functioning. Clinicians often order the PFA-100 / 200 when someone has unexplained bleeding, bruising, or before surgeries to screen for clotting issues. It reflects primary hemostasis and blood–vessel interactions in a way that standard platelet counts or PT/PTT can’t. Patients sometimes feel a bit anxious or confused seeing “PFA-100 results” on their report, wondering “what’s normal?” or “am I at risk?” This test helps bridge that gap.

Purpose and Clinical Use

Why do doctors order the Platelet Function Analyzer (PFA-100 / 200)? Mostly it’s to screen for platelet dysfunction in bleeding disorders, monitor anti-platelet therapy (like aspirin or clopidogrel), or evaluate unexplained mucosal bleeding (nosebleeds, heavy periods). It’s not a diagnostic stand-alone, but a supportive piece of clinical puzzle. If your cardiologist wants to check how well your anti-platelet drug is working, they might look at PFA-100 interpretation. If you’ve got a family history of Von Willebrand’s disease or have had post-surgical bleeding, your hematologist may ask for a PFA-200 run. In any case, this analyzer gives practical insight into how your platelets plug a vessel injury—without sending you straight to a biopsy or imaging test.

Test Components and Their Physiological Role

The Platelet Function Analyzer (PFA-100 / 200) simulates a small vessel injury in vitro under high shear conditions. Its core components include:

  • Citrated whole blood sample – preserves platelets by chelating calcium, halting clotting until testing begins.
  • Cartridge with membrane – lined with collagen and either epinephrine (CEPI cartridge) or ADP (CADP cartridge). These agonists trigger platelet activation.
  • Pistons and vacuum pump – pull the sample through a microscopic aperture within the membrane, mimicking blood flow through a small vessel.
  • Closure time measurement – time needed for platelets to form a plug that occludes the aperture, reported in seconds.

Platelet Function Analyzer meaning is rooted in measuring adhesion, activation and aggregation steps: first, collagen exposure makes platelets change shape and adhere; then epinephrine or ADP amplify the signal, making platelets stick together. It’s kind of like a miniaturized bleeding wound test. The PFA-100 / 200 reflects vessel wall interactions, platelet receptor function (GPIb, GPIIb/IIIa), secretion of granules, and even influences from von Willebrand factor under flow. Each cartridge component has a specific physiological role: collagen to mimic subendothelial matrix, epinephrine or ADP to represent hormonal and paracrine signals that modulate platelet plug formation.

Physiological Changes Reflected by the Test

Alterations in Platelet Function Analyzer results reflect shifts in primary hemostasis. If closure time is prolonged, it suggests issues with platelet adhesion or aggregation. For example:

  • Increased closure time: could indicate thrombocytopenia, von Willebrand factor deficiency, genetic GPIIb/IIIa defects, or medication effects (like aspirin, NSAIDs, or P2Y12 inhibitors).
  • Decreased or normal closure time: typically fine but may be misleading in very high platelet counts or hypercoagulable states (early polycythemia vera sometimes shows near-normal results despite altered function).

It’s important to know that transient changes (like after a heavy workout, acute infection, or even high stress) can shift PFA-100 results temporarily. Inflammation often bumps up von Willebrand factor, speeding closure times. Conversely, acute blood loss or massive fluid infusion dilutes platelets, prolonging closure. Hence, not every change means long-term disease; sometimes your last marathon or a bad cold is the reason.

Preparation for the Test

Proper prep optimizes Platelet Function Analyzer interpretation. Here’s what generally matters:

  • Medications & supplements: Stop aspirin, NSAIDs 5–7 days before if clinically safe; clopidogrel, ticagrelor need at least 5 days. Fish oil, Ginkgo biloba, vitamin E might also affect results—ask your doc if you can hold them.
  • Hydration: Dehydration thickens blood; drink water unless restricted.
  • Fasting: Usually not required, but a fatty meal might transiently affect platelet membrane fluidity—so a light breakfast is fine.
  • Physical activity: Avoid vigorous exercise for 24 hours; intense workouts can activate platelets or cause mild inflammation.
  • Circadian rhythm: Platelet activity fluctuates diurnally (higher in morning). Consistent timing (am vs pm) helps comparability.
  • Recent illness: Acute infections, fevers, or inflammatory states can alter von Willebrand factor and platelet reactivity; best to wait 2 weeks post-illness for baseline testing.

Remember, each lab’s PFA-100 / 200 protocol may tweak these guidelines. Always confirm with the ordering physician or lab techs their specific prep instructions.

How the Testing Process Works

Once you’re prepped, a phlebotomist draws citrated whole blood—usually 2–3 mL—into a special tube. The sample is gently inverted, then loaded into the PFA-100 or PFA-200 cartridge. The device then pumps blood through the membrane, simulating shear rates of small arterioles. It takes about 4–10 minutes per cartridge. You’ll feel just a normal blood draw—no extra poke or discomfort. Short-term reactions are rare: mild bruising at the needle site or transient lightheadedness if you’re needle-averse. The machine spits out “closure times” in seconds; technicians compare them to lab-specific reference ranges and report them in the lab report.

Reference Ranges, Units, and Common Reporting Standards

Platelet Function Analyzer results are reported as closure time in seconds. Depending on the cartridge, you’ll see “CEPI closure time” (collagen/epinephrine) and “CADP closure time” (collagen/ADP). Labs label these under headings like “PFA-100 Reference Range” or “Expected Values.” Importantly, these ranges derive from healthy donors tested on the same PFA-100 / 200 model using identical reagents. Because different lots of cartridges or slightly different protocols can shift numbers, your lab’s normal for CEPI might be 75–165 seconds, whereas another lab sees 80–180. That variation is why clinicians always look at your specific lab’s units and reference ranges—rather than textbook ones—when interpreting your results.

How Test Results Are Interpreted

Interpreting Platelet Function Analyzer results is an art informed by science. Clinicians review CEPI and CADP closure times in context of your history. Key points:

  • Single vs paired results: A solitary prolonged CEPI might reflect aspirin effect; if CADP is normal, that’s consistent with COX-1 inhibition rather than intrinsic platelet defect.
  • Trends over time: Serial PFA-100 tests can monitor therapy adherence (for example, clopidogrel response) or disease progression—one isolated normal result rarely closes the case.
  • Clinical correlation: Prolongation without any bleeding symptoms may warrant watchful waiting; severe bleeding with near-normal closure times may lead to additional tests (platelet aggregation studies, von Willebrand panels).

Ultimately, Platelet Function Analyzer interpretation always depends on your clinical scenario—symptoms, medications, comorbidities—and not solely on a numeric cut-off.

Factors That Can Affect Results

Many influences can nudge your Platelet Function Analyzer results up or down. These factors include:

  • Medications: Aspirin irreversibly inhibits COX-1, prolonging CEPI closure times; NSAIDs have similar but shorter effects. P2Y12 antagonists (clopidogrel, prasugrel) prolong CADP. Steroids may mildly increase aggregation.
  • Supplements: Fish oil, garlic, ginger, ginkgo biloba, and other herbal products can inhibit platelet function; vitamin C in high doses might enhance aggregation.
  • Diet: High-fat meals alter platelet membrane lipid composition transiently; fasting state vs fed state matters slightly.
  • Exercise: Strenuous workouts raise catecholamines and vWF levels, typically shortening closure times; long-term athletic training might lead to baseline shifts.
  • Hydration & blood volume: Dehydration concentrates blood, possibly speeding closure; overhydration or IV fluids can dilute platelets, prolonging times.
  • Stress & emotional state: Acute stress elevates epinephrine in vivo, priming platelets; cortisol spikes in chronic stress may alter receptor sensitivity.
  • Inflammation & illness: Acute infections ramp up acute phase reactants, especially vWF; autoimmune diseases like SLE or ITP can both shorten or prolong depending on stage.
  • Hematocrit & red cell interactions: Low hematocrit slows shear stress across the aperture; high hematocrit increases it.
  • Sample handling: Vigorous shaking of the tube can activate platelets prematurely; testing delays beyond 2 hours may degrade function.
  • Device variability: Differences between PFA-100 vs PFA-200 models, cartridge lots, lab technologist technique, and calibration all matter.

Given this complexity, your clinician often asks about recent activities, diet, supplements or any stress before interpreting your PFA-100 / 200 report, so they can make sense of any unexpected results.

Risks and Limitations

The Platelet Function Analyzer (PFA-100 / 200) is generally safe, but like any test, it has limitations and minor risks:

  • False positives: Temporary drug effects (e.g. NSAIDs), recent workouts, or improper sample handling may prolong closure times, suggesting a problem where none exists.
  • False negatives: High platelet counts or elevated vWF in inflammation can mask mild platelet defects, giving normal closure times despite mild dysfunction.
  • Biological variability: Yourself may have slightly different results each day, depending on circadian rhythms and transient states.
  • Not a standalone diagnose: PFA-100 results alone can’t pinpoint specific receptor defects or von Willebrand disease subtypes; further specialized tests (aggregometry, vWF multimers) are often needed.
  • Procedural risk: Minimal bleeding or bruising at the venipuncture site; very rare hematoma or infection.

In short, the Platelet Function Analyzer is a valuable screening and monitoring tool, but it’s one piece of a larger diagnostic puzzle.

Common Patient Mistakes

Patients sometimes unwittingly skew their Platelet Function Analyzer results by:

  • Forgetting to hold aspirin or NSAIDs before the test, leading to prolonged CEPI closure.
  • Continuing herbal supplements (like ginkgo or garlic) without mentioning them to the lab.
  • Arriving dehydrated or after vigorous exercise, altering basal platelet reactivity.
  • Expecting the test to give a definitive diagnosis of bleeding disorders and being confused by “just” closure times.
  • Requesting repeat PFA-100 / 200 tests within days for reassurance, despite no clinical indication—laboratory variability can make slight changes normal.

Asking your provider for clear instructions on medication holds, hydration, and timing can help avoid these pitfalls.

Myths and Facts

There are a few myths floating around Platelet Function Analyzer testing:

  • Myth: “PFA-100 / 200 can diagnose von Willebrand disease alone.”
    Fact: It screens for platelet–vWF interactions but can’t subtype vWD; further vWF antigen, activity and multimer analysis are needed.
  • Myth: “If PFA closure time is normal, I have no bleeding risk.”
    Fact: Normal closure doesn’t exclude mild platelet receptor defects or coagulation factor issues; clinical history still counts.
  • Myth: “Aspirin should never be stopped before testing; you want to see the drug effect.”
    Fact: If you’re being screened for an inherent platelet disorder, withholding aspirin improves accuracy. If monitoring antiplatelet therapy, you’d take it as prescribed.
  • Myth: “One test is enough forever.”
    Fact: Repeated PFA-100 / 200 tests can show different results due to biological variants; follow-up depends on symptoms and treatment changes.

Correcting these misconceptions helps patients appreciate what the Platelet Function Analyzer really measures and why context is king.

Conclusion

The Platelet Function Analyzer (PFA-100 / 200) is a specialized tool to evaluate primary hemostasis by measuring platelet adhesion and aggregation under flow. It includes citrated whole blood, collagen/epinephrine or collagen/ADP cartridges, and provides closure times that reflect how effectively platelets stop bleeding. Understanding PFA-100 interpretation, preparation requirements, and factors affecting results empowers patients to participate actively in their care. The test is quick, minimally invasive, and offers clinicians valuable screening, monitoring, and risk-assessment data when used alongside clinical evaluation and other laboratory assays.

Frequently Asked Questions

  • 1. What does the Platelet Function Analyzer (PFA-100 / 200) measure?
    It measures closure time: how long platelets take to form a plug under flow conditions over a collagen/epinephrine or collagen/ADP membrane, simulating small vessel injury.
  • 2. Why is the PFA-100 test ordered?
    To screen for platelet dysfunction in unexplained bleeding, monitor anti-platelet therapy effectiveness, and assess von Willebrand factor interactions in primary hemostasis.
  • 3. How should I prepare for the PFA-100 / 200?
    Avoid aspirin/NSAIDs 5–7 days prior if clinically safe, hold supplements like fish oil or Ginkgo, stay hydrated, skip intense workouts 24 hours before, and schedule consistently morning or afternoon.
  • 4. What is a CEPI cartridge?
    CEPI stands for collagen/epinephrine cartridge. It assesses platelet function when both adhesion (collagen) and activation (epinephrine) pathways are involved.
  • 5. How long does the test take?
    The blood draw takes a few minutes; each PFA cartridge run is about 4–10 minutes. You’re usually done within half an hour including setup.
  • 6. Are there any risks?
    Minimal: mild bruising or discomfort at the needle site. No extra procedural risks since it’s a standard phlebotomy sample.
  • 7. Can dehydration affect my results?
    Yes—dehydration concentrates blood, often shortening closure time. Being well-hydrated yields more consistent results.
  • 8. Does a normal PFA-100 mean I have no bleeding disorder?
    Not necessarily. Normal closure suggests primary hemostasis is likely adequate, but coagulation factor defects or mild platelet receptor issues may still be present.
  • 9. Why are there two cartridges (CEPI and CADP)?
    They use different agonists. CEPI highlights aspirin-like drug effects; CADP (collagen/ADP) is less sensitive to COX-1 inhibitors, helping differentiate drug vs intrinsic platelet defects.
  • 10. Can stress or illness change my PFA results?
    Definitely. Acute infection or inflammation raises vWF and platelet activation, often shortening closure time. Chronic stress may also alter platelet reactivity.
  • 11. How do labs report PFA-100 results?
    As closure time in seconds, with CEPI and CADP values. Reports include your lab’s reference range (normal interval) derived from healthy subjects using the same methods.
  • 12. What if one cartridge shows prolonged closure and the other is normal?
    Commonly seen with aspirin effect—prolonged CEPI, normal CADP. It suggests COX-1 inhibition rather than intrinsic platelet receptor defect.
  • 13. Is repeated testing needed?
    Only if monitoring anti-platelet therapy, following bleeding symptoms, or reassessing after holding interfering meds. Otherwise, one baseline test plus clinical correlation suffices.
  • 14. How do sample handling errors affect PFA?
    Shaking the citrated tube too much pre-analysis can pre-activate platelets, shortening closure time artificially; delays beyond 2 hours reduce platelet responsiveness, prolonging results.
  • 15. Who interprets my Platelet Function Analyzer results?
    A hematologist or coagulation specialist usually reviews PFA-100 / 200 reports in conjunction with your history, medications, and other labs to guide next steps.
Written by
Dr. Aarav Deshmukh
Government Medical College, Thiruvananthapuram 2016
I am a general physician with 8 years of practice, mostly in urban clinics and semi-rural setups. I began working right after MBBS in a govt hospital in Kerala, and wow — first few months were chaotic, not gonna lie. Since then, I’ve seen 1000s of patients with all kinds of cases — fevers, uncontrolled diabetes, asthma, infections, you name it. I usually work with working-class patients, and that changed how I treat — people don’t always have time or money for fancy tests, so I focus on smart clinical diagnosis and practical treatment. Over time, I’ve developed an interest in preventive care — like helping young adults with early metabolic issues. I also counsel a lot on diet, sleep, and stress — more than half the problems start there anyway. I did a certification in evidence-based practice last year, and I keep learning stuff online. I’m not perfect (nobody is), but I care. I show up, I listen, I adjust when I’m wrong. Every patient needs something slightly different. That’s what keeps this work alive for me.
FREE! Ask a Doctor — 24/7,
100% Anonymously

Get expert answers anytime, completely confidential. No sign-up needed.

Articles about Platelet Function Analyzer (PFA-100 / 200)

Related questions on the topic